QUICK REFERENCE CHART NORMALLY CLOSED & NORMALLY OPEN
The sport indicated on the effective area present the more the better.
PHOTO
MODEL
PIPE SIZE
MATERIAL
OPERATING PRESSURE
kgf/cm 2
FLUID TEMP ° C
FLUID
STEAM
WATER
AIR
OIL
GAS
VACUUM
UD-6
UD-8
1/8"~1/4"
Brass
0-7
-5℃ ︴80℃
●
●
●
●
●
●
●
●
●
●
●
●
UD-10
3/8"
Brass
0-10
-5℃ ︴80℃
●
●
●
●
●
●
●
●
●
●
●
●
UD-15
1/2"
Brass
0-3
-5℃ ︴80℃
●
●
●
●
●
●
●
●
●
●
●
●
UD-6
UD-8
1/8"~1/4"
CF8M
0-7
-5℃ ︴185℃
●
●
●
●
●
●
●
●
●
●
●
SUS-10
3/8"
CF8M
0-10
-5℃ ︴185℃
●
●
●
●
●
●
●
●
●
●
●
UPS
1/2"~1"
Brass
0.2-10
-5℃ ︴185℃
●
●
●
●
●
●
●
●
●
●
●
SUS#316
1/2"~2"
CF8M
0.2-10
-5℃ ︴185℃
●
●
●
●
●
●
●
●
●
●
●
US
1/2"~2"
Bronze
0.5-15
-5℃ ︴185℃
●
●
●
●
●
●
●
●
●
●
●
USF
1/2"~2"
Bronze
0.5-15
-5℃ ︴185℃
●
●
●
●
●
●
●
●
UW
1/2"~2"
Bronze
0-5
-5℃ ︴80℃
●
●
●
●
●
●
●
●
The details of each model , please refer to next each page.
The standard voltage: AC110V/220V 50/60HZ)
Other voltage of AC/DC and normally open are available when required.
"*" Special Order.
SOLENOID VALVE-SERIES 2
QUICK REFERENCE CHART NORMALLY CLOSED & NORMALLY OPEN
The sport indicated on the effective area present the more the better.
PHOTO
MODEL
PIPE SIZE
MATERIAL
OPERATING PRESSURE
kgf/cm 2
FLUID TEMP ° C
FLUID
STEAM
WATER
AIR
OIL
GAS
VACUUM
UWF
1/2"~2"
Brass, Bronze *
0-5
-5℃ ︴80℃
●
●
●
●
●
●
●
●
SUW
#316
1/2"~2"
CF8M
0-5
-5℃ ︴80℃
●
●
●
●
●
●
●
●
SUWF
1/2"~2"
CF8M *
0-5
-5℃ ︴80℃
●
●
●
●
●
●
●
●
UWF
1 1/4"~4"
FC-20
0.2-8
-5℃ ︴80℃
●
●
●
●
●
●
USF
1 1/4"~4"
FC-20
0.5-10
-5℃ ︴185℃
●
●
●
●
●
●
●
●
●
●
●
UG
3/8"~2"
Bronze
0-7
-5℃ ︴80℃
●
●
●
●
●
●
●
●
●
●
UAW
1/2"~2"
Bronze
0.5-15
-5℃ ︴80℃
●
●
●
●
●
●
UA-8
UA-10
1/4"~3/8"
Brass
0-7
0-10
-5℃ ︴80℃
●
●
●
●
●
●
●
●
●
UAO
1/4"~1/2"
Brass
0.5-15
-5℃ ︴80℃
●
●
●
●
●
●
UD
(NO)
1/8"~3/8"
Brass
0-7
0-10
-5℃ ︴80℃
●
●
●
●
●
●
●
●
●
●
●
●
The details of each model , please refer to next each page.
The standard voltage: AC110V/220V 50/60HZ)
Other voltage of AC/DC and normally open are available when required.
"*" Special Order.
SOLENOID VALVE-SERIES 3
QUICK REFERENCE CHART NORMALLY CLOSED & NORMALLY OPEN
The sport indicated on the effective area present the more the better.
PHOTO
MODEL
PIPE SIZE
MATERIAL
OPERATING PRESSURE
kgf/cm 2
FLUID TEMP ° C
FLUID
STEAM
WATER
AIR
OIL
GAS
VACUUM
SUS
(NO)
1/4"~3/8"
CF8M
0-7
0-10
-5℃ ︴80℃
●
●
●
●
●
●
●
●
UW
(NO)
3/8"~1/2"
Brass, Bronze
0-5
-5℃ ︴80℃
●
●
●
●
●
●
●
●
SUW
(NO)
1/2"~2"
CF8M
0-5
-5℃ ︴80℃
●
●
●
●
●
●
●
●
UDC
1/4"~1/2"
PVC
0-1
-5℃ ︴80℃
●
●
●
UDC-TF
1/2"~4/3"
PTEF
0-1
0-0.5
-5℃ ︴80℃
●
●
●
SUS#304
1/2"~1"
#304
0.5-15
-5℃ ︴185℃
●
●
●
●
●
●
●
●
●
●
●
PKW
explosion-proof
3/8"~1"
forging copper
0-5
-5℃ ︴70℃
●
●
●
●
●
●
●
●
●
●
●
●
●
●
SKW
explosion-proof
1/2"~1"
#316
0-10
0-5
-5℃ ︴70℃
●
●
●
●
●
●
●
●
●
●
●
●
●
●
PKS
explosion-proof
1/2"~1"
forging copper
0.2-10
-5℃ ︴70℃
●
●
●
●
●
●
●
●
●
●
●
SKS
explosion-proof
1/2"~1"
#316
0.2-10
-5℃ ︴70℃
●
●
●
●
●
●
●
●
●
●
●
UPS
(NO)
1/2"~1"
Brass *
0.2-10
-5℃ ︴185℃
●
●
●
●
●
●
●
●
●
●
SUS
(NO)
1/2"~2"
CF8M *
0.2-10
-5℃ ︴130℃
●
●
●
●
●
●
●
●
●
●
UWF
(NO)
1 1/4"~4"
FC-20 *
0.2-8
-5℃ ︴80℃
●
●
●
●
●
●
USF
(NO)
1 1/4"~4"
FC-20 *
0.2-10
-5℃ ︴185℃
●
●
●
●
●
●
●
The details of each model , please refer to next each page.
The standard voltage: AC110V/220V 50/60HZ)
Other voltage of AC/DC and normally open are available when required.
"*" Special Order.
SOLENOID VALVE-SERIES 2
QUICK REFERENCE CHART NORMALLY CLOSED & NORMALLY OPEN
The sport indicated on the effective area present the more the better.